Miêu tả Mạch đo tụ điện Cuộn cảm LC100A
LC-100A Meter based on the LC resonant principle, add in high speed microcontroller’s precision computation. The meter has wide measurement range and high precision, it’s measuring range below 1uH and 1pF. Small size, light weight and easy to carry.
Chức năng
-
- Size: 8cm x 5cm x 2cm (L x W x H)
- Model: LC100-A
- Based on the L/C resonance principle
- High speed microcontroller’s precision computation
- Measuring range below 1uH and 1pF
- Supply power:+5v ,mini USB interface
- Measurement accuracy: 1%
- Capacitance measuring range: 0.01 pF – 10uF (The minimum resolution: 0.01 pF )
- Inductance measuring range: 0.001 uH – 100mH
- Big inductance measuring range: 0.001 mH – 100H (The minimum resolution: 0.001uH )
- Test frequency range: L/C about 500KHZ/Big inductance 500HZ
- Effective display digits: 4 digits
- LCD display mode: 1602

Function of five buttons:
-
- Red: Reset (Momentary Push Button)
- White: High Capacitance Hi.C Choice (Alternate Action)
- Blue: High Inductance Hi.L Choice (Alternate Action)
- Yellow: L/C (Alternate Action)
- Red Mini: Function button
- Details as follows (Press “1”, Release “0”, “X” random)
Test Frequency
-
- L Range, C Range: 500kHz
- Hi.L Range: 500Hz~50KHz
- Resolution (Hi.C Range): 0.01uF
- Resolution (Hi.L Range): 0.001mH
- Resolution (L Range): 0.001uH
- Resolution (C Range): 0.01pF
Note:
1. Please reset to “0” before testing a capacitance or an inductance, or errors may be appeared. Even if “0” displayed before measuring, resetting to “0” is needed.
2. At the time of resetting to “0”, when “CALCULATING…OK” appears, please keep holding button for 2 to 3 seconds, and “<DATA SAVED>” will be displayed. Now release button.
3. DO NOT Reset to “0” while components are being measured. If you do it, please shut down immediately and restart, then reset to “0”.
4. The test time of a large capacitance (above 10mF) may be as long as seven to eight seconds (100mF).
5. DO NOT measure a capacitance which is not discharged, otherwise it may damage the meter.
6. DO NOT Use different (Longer) test leads other than those supplied Longer Leads can affect the accuracy of the meter
Video sản phẩm
Tài liệu liên quan
DỊCH VỤ
THÔNG TIN LIÊN HỆ
-
- Zalo & Sdt: 0939 395 952
- Email: dientuxanhvn@gmail.com
- Website 01: www.dientuxanh.vn
- Website 02: www.dtxvn.com

EV2300 HPA002 Texas Instruments
Module Lora E22-400T30S UART 433mhz 10km
USB TO RS485 TTL FT232
DTX LoRa IOT Shield – RN2483
DTX BlackBoard IOT M95
Module GPS Quectel LC86LICMD
Module Lora E22-400T33S UART 433mhz 16km
DTX LoRa Transceiver RN2483
NX8048P070-011R - Màn hình 7.0 INCH TFT Nextion
Module 4G Quectel EC25EFA-512-STD
Mạch đo tụ điện cuộn cảm LC100A
Mạch nạp ST-Link V2
Module LoRa LoRa610Pro Mesh 3km
NX4827K043 - Màn hình 4.3 INCH TFT Nextion
Board phát triển Ethernet Board W5500
Thiết bị điều khiển đèn biển - Lighthouse Led 01
Module 4G Quectel EC21VFA-512-STD
Bộ điều khiển đèn DALI DIM NEMA
Mạch Khuếch Đại Âm Thanh XH-M190 2x100W
Máy phát xung XY-PWM
Module Zigbee E18-MS1PA1-IPX 








Đánh giá
Chưa có đánh giá nào.